PRESSURE TESTING, LEAK REPAIRS, COMPLIANCE AUDITS & MAINTENANCE.
Protect your asset integrity, maintain statutory compliance, and eliminate unplanned downtime with comprehensive pressure testing, gas leak detection and leak repairs, removing water from gas installations, commercial fire water maintenance, mandatory annual backflow testing, compliance auditing, and lifecycle maintenance across Western Australia.

Full Lifecycle Integrity
Perth & Statewide WA Mobilisation
Turnkey Compliance Across Western Australia.
Gas, fire water, and hydraulic infrastructure is a high-consequence asset class. Regulatory non-compliance, undetected gas leaks, water ingress in gas lines (such as burst water mains jetting into adjacent gas piping), overdue backflow prevention testing, drifting pressure regulators, or aging burner controls expose facility owners to safety hazards, insurance invalidation, and costly production shutdowns.
Because our tradesmen hold Unrestricted Class G, Unrestricted Class I(A), and Class I(B) gasfitting permits alongside WA Plumbing Contractor and Electrical licences, we inspect, service, and maintain your entire site under one roof, from commercial gas installations, fire water services, testable backflow devices, water supply, sanitary, and drainage systems right through to industrial gas piping operating above 200 kPa and Type B process burners of any GJ capacity.
Statutory Authorisations
- Unrestricted Class G Gasfitting PermitAS/NZS 5601.1 & AS/NZS 1596
Authorised for all general commercial and industrial Natural Gas and LPG installations and Type A gas appliances (AS/NZS 5601.1 and AS/NZS 1596).
- Class I(A) Gasfitting PermitAS 3814 & AS 1375
We hold a full unrestricted Class I(A) gas licence, authorising us to install, commission, and service Type B gas appliances and industrial fuel-fired equipment (AS 3814 and AS 1375).
- Class I(B) Gasfitting PermitAll Pressures (<200 & >200 kPa)
Authorised for gasfitting work on consumer piping systems operating above 200 kPa, alongside all standard low and medium pressure tiers (<200 kPa).
- WA Plumbing Contractor & Electrical LicencesAS/NZS 3500 & NCC
Authorised across commercial and industrial water supply, sanitary, drainage, fire water services, and testable backflow prevention (AS/NZS 3500, AS 2419.1, AS 2441, and the National Construction Code), alongside licensed electrical capabilities for burner controls and plant integration.
Our Lifecycle Services.
Pneumatic & Hydrostatic Pressure Testing
Certified strength and tightness testing of new, modified, and existing gas, fire water, and water pipelines across all pressure regimes (both under 200 kPa and >200 kPa Class I(B) systems), complete with calibrated gauge/chart recorder verification and NATA-traceable test documentation.
Water Removal from Gas Piping, Ingress Repair & Gas Leak Detection
Experienced in water removal from gas piping and complete pipeline repair, including water ingress caused by burst water pipes jetting into gas lines, cross-connections, or flooding. We repair both the water and gas pipework, extract water from lines, meters, regulators, and appliances, and purge and recommission the gas system.
Commercial Fire Water Services & Backflow Prevention Testing
We specialise in commercial fire water services and the installation, maintenance, and mandatory annual testing of testable backflow devices, including Double Check Valves (DCVs) and high-hazard Reduced Pressure Zone Devices (RPZDs). We also provide expert mechanical repairs, fire hose reel change-outs, and landing valve replacements to ensure compliance with AS/NZS 3500.1, AS 2419.1, and AS 2441.
Compliance Audits & Gap Analysis
Thorough site-wide audits against AS/NZS 5601.1, AS 3814, AS 1375, AS/NZS 1596, AS 2896, AS/NZS 3500, AS 2419.1, AS 2441, and the National Construction Code (NCC). We deliver clear, prioritized engineering reports identifying non-conformances, corrosion risks, ventilation deficits, and signage/labeling gaps, paired with practical rectification scopes.
Statutory Inspections & Preventative Maintenance
Scheduled servicing of Type A and Type B gas appliances, commercial hot water and pool heating plants, backflow and water supply systems, valve train leak testing, safety shut-off valve actuation checks, BMS flame-failure response testing, regulator overhaul, and combustion efficiency tuning.
Inert Purging, Upgrades, PE Tie-Ins & Corrosion Remediation
Safe nitrogen purging, gas-free verification, and mechanical isolation of redundant plant, plus turnkey execution of audit rectification works, regulator upgrades, below-ground PE electrofusion and butt-welded extensions, and protective wrapping/coating remediation using Stopaq, Canusa, Denso, and Solartech.
Need a Rapid Quote, Pre-Qualification Pack, or Technical Consultation?
Speak directly with our Western Australian commercial and industrial gas engineering team for upcoming shutdowns, brownfield upgrades, compliance audits, or greenfield capital works.
Direct Procurement & Vendor Details
- Phone1300 779 171
- Australian Business NumberABN 78 714 615 245
- HeadquartersCommercial Operations Center, Perth, Western Australia
Explore Other Specialist Gas Capabilities.
Commercial & Industrial Gasfitting & Plumbing
All-pressure commercial and industrial gasfitting (<200 kPa and >200 kPa), Type A and Type B appliance piping, gas leak detection and leak repairs, water removal from gas installations, below-ground PE piping, commercial fire water services, backflow testing, and water supply, sanitary, and drainage plumbing.
Type B Gas Appliances, BMS & Special Applications
Full unrestricted Class I(A) gasfitting to install, commission, and service Type B gas appliances, valve trains, Burner Management Systems (BMS), incinerators, cremators, smoke ovens, coffee roasters, and gas engines.
Medical & Laboratory Gas Pipeline Systems
AS 2896 compliant medical and lab pipelines for Medical O₂, Medical Air, N₂O, CO₂, N₂, Medical Vacuum, Surgical Air, and WAGD.
Process, Shielding, Instrument & Biomethane Gases
Shielding and fuel gases (Argon, CO₂, O₂, Acetylene, LPG to AS/NZS 1596), high-purity instrument gas lines, and biomethane / renewable gas infrastructure for processing and power generation.
HSEQ, Licences, Insurances & WA Mobilisation
WHS Act & High Risk Construction Work (HRCW) compliance, WHS (Mines) Regulations & Mine Safety Management System (MSMS) integration, High Risk Work Licences, excavation & asset locating, and WA mobilisation.